| Measuring range: -7.6 Ö +7.6 mV/V |
| Input sensitivity: 0.02 µV/count |
| Full scale non-Linearity: <0.01% |
| Gain drift: 0,001% FS/¡C |
| Display: 6 digit, 7-segment LED red, height 8mm |
| A/D Converter: 24 bit |
| Internal Resolution: > di 16.000.000 points |
| Visible resolution (in divisions): 999999 |
| Divisions value (adjustable): x1, x2, x5, x10, x20, x50 |
| Decimal figures range: 0 Ö 4 |
| Temperature range: -10 Ö +50¡C (max umidity 85% without condensation) |
| Storage temperature: -20 Ö +60¡C |
| Filter: 0.1 Ö 250 Hz |
| Excitation voltage: 4 Vdc (max 4 -350 Ohm- load cells) |
| Logic output: 2 optoisolated outputs; max 24 Vdc/100 mA each |
| Logic input: 2 optoisolated inputs 24 Vdc PNP (external power supply) |
| Serial port: 1 USB-C device + 1 RS232C and 1 RS485 with ASCII or Modbus RTU protocol or 1 Fieldbus |
| Analog output Non-Linearity: <0.03% |
| Temperature drift analog output: 0,002% FS/¡C |
| Power supply: 24 Vdc ±10% – power consumption 5 W |
| Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard via USB |
| Data storage: 32 Kbytes expandable up to 1024 Kbytes (optional) |
| Regulatory compliance: EN61000-6-2, EN61000-6-3, EN61326-1 for EMC, EN61010-1 for Electrical Safety |
DAT 11
FEATURES
- Up to 4 load cell connections in parallel
- Multiple fieldbus configurations
- Mechanical keypad
- DIN rail mount
- Peak hold function for dynamic measurement
- Removable terminal blocks
- OPTIMATION¨ software for USB PC connection
- Engineered and manufactured in Italy
The DAT 11 is the fastest weight transmitter for receiving, converting, and transmitting data due to its high-performance A/D converter. It has a small size and compact design, allowing it to be inserted in many different applications while taking up minimal space. Customizable with a built-in mechanical keyboard with programmable key block, it is possible to manually set the weight filter with predetermined values, or with individually adjustable parameters. It features removable screw terminal blocks, a selectable logic input function, voltage or current analog input, unipolar or bipolar analog output, RS485 junction box connection and peak hold function for dynamic measurements. It is EN45501 compliant, and the fieldbus has been updated to 125Hz. A USB port is built in for firmware updates, using PavoneÕs Optimation software on a PC, as well as for connection to the TESTER 1008 for calibration and troubleshooting. Dead Weight, Theoretical, and Data Sheet calibrations are available, as well as linearization of a 5 point weight calibration. PavoneÕs proprietary Optimation software allows for easily performing various operations, such as configuring the instrument and securely saving information through the DATALOGGER function.

DAT-1400